1.Kyoritsu 6305
THÔNG SỐ KỸ THUẬT: + Chỉ thị số + Sơ đồ nối dây : 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W + Điện áp : 150 / 300 / 600V + Dòng điện: 3000A Phụ kiện bao gồm : + 8125 (kìm đo 500A) 3 cái + 7141B (dây đo điện áp), + 7148 (Cáp USB), + 7170 (Dây nguồn), + 8326-02 (thẻ SD [2GB]) × 1 + 9125 (túi đựng), Phần mềm PC , pin × 6, hướng dẫn sử dụng Phụ kiện tùy chọn : 8124,8125,8126,8127,8128 (kìm đo). 8129 (kìm đo dây mềm). 8312 (adapter nguồn) 8322 (Compact flash card 256MB) 8323 (Compact flash card 1GB) 9132 (Carrying case with magnet) Wide range of clamp sensor up to 1000A on request. Bảo hành : 12 tháng Hãng sản xuất : Kyoritsu - Nhật Xuất xứ : Nhật Giá bán: 23.920.000 vnđ
• | Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems | • | Voltage, Current, Power Factor and Frequency measurements | • | Power analysis (Active, Apparent and Reactive power) | • | Energy analysis (Active, Apparent and Reactive power) | • | Active power accuracy: ±0.3%rdg±0.2%f.s. | • | Automatic wiring check function to prevent incorrect connections | • | Large memory capability (2GB) using built-in SD card interface | • | Real time & remote measurements using Android application | • | synchronous measurements between two units of KEW 6305 | • | Wide selection of clamp sensors allow measurements from 0.1A to 3000A | • | The instrument automatically recognizes what kind of clamp sensor is connected to it |
| | • | Windows software for data analysis and setting via USB port or Bluetooth | | Free Android software "KEW smart 6305" is available on "Google Play Store" (*)- Supporting Android ver. 2.2 - 4.0
- WVGA (800 × 480) resolution or higher
 |
 | (*) | Please search "KEW Smart" in Google Play Store. Communication charge may be incurred separately to download application. |  |
|
| |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Wiring connections |  |  |  | 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Measurements |  |  |  | Voltage, Current, Frequency, Active power |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Parameters |  |  |  | Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Power factor (cos θ), Neutral current |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Voltage : |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Ranges [RMS] |  |  |  | 150.0 / 300.0 / 600.0V |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Allowable input |  |  |  | 10~110% of rating range |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Display ranges |  |  |  | 5~130% of each range |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Accuracy |  |  |  | ±0.2%rdg±0.2%f.s. (sine wave, 45~65Hz) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Current : |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Ranges [RMS] |  |  |  | 8128 ( | 50A | type ) | : | 1.000 / 5.000 / 10.00 / 25.00 / 50.00A / auto | 8127 ( | 100A | type ) | : | 2.000 / 10.00 / 20.00 / 50.00 / 100.0A / auto | 8126 ( | 200A | type ) | : | 4.000 / 20.00 / 40.00 / 100.0 / 200.0A / auto | 8125 ( | 500A | type ) | : | 10.00 / 50.00 / 100.0 / 250.0 / 500.0A / auto | 8124 ( | 1000A | type ) | : | 20.00 / 100.0 / 200.0 / 500.0 / 1000A / auto | 8129 ( | 3000A | type ) | : | 300.0 / 1000 / 3000A |
|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Allowable input |  |  |  | 10~110% of each range |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Display ranges |  |  |  | 1~130% of each range |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | ![]() |  | Accuracy |  |  |  | ±0.2%rdg±0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45~65Hz) (*) +1%f.s. at the lowest range |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Crest factor |  |  |  | Voltage: up to 2.5, Current: up to 3.0 (with 90% fs or less) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Active power accuracy |  |  |  | ±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor (*) +1%f.s. when the lowest current ranges is selected. |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Effect of power factor |  |  |  | Active power: ±1.0%rdg cos θ=±0.5 (PF=1) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Frequency meter range |  |  |  | 40.0~70.0Hz |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Frequency meter accuracy |  |  |  | ±3dgt |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Accuracy precondition |  |  |  | PF=1, Sine wave, 45~65Hz, 23ºC±5ºC |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Display update period |  |  |  | 1 second |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Operating temperature and humidity range |  |  |  | 0~+50ºC, less than 85%RH (without condensation) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Storage temperature and humidity range |  |  |  | -20~+60ºC, less than 85%RH (without condensation) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | PC communication interface |  |  |  | USB, Bluetooth |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | PC card interface |  |  |  | SD card (2GB) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Applicable standards |  |  |  | IEC 61010-1 CAT.III 600V |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Power supply (AC Line) |  |  |  | AC100~240V±10% (50/60Hz) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Power supply (DC battery) |  |  |  | LR6 or Ni-MH (HR-15-51) ×6 (Battery charger not included), Battery life approx. 15h (LR6) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Power consumption |  |  |  | 10VA (max.) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Dimension |  |  |  | 175(L)×120(W)×65(D) mm |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Weight |  |  |  | Approx. 800g (including batteries) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Accessories |  |  |  | 7141B (Voltage test lead set: 4pcs) 7148 (USB cable) 7170 (Power cord) 9125 (Carrying case) 8326-02 (SD card 2GB) KEW WINDOWS (PC Software) Battery (LR6)×6 Quick manual Calibration certificate |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Optional |  |  |  | 8124, 8125, 8126, 8127, 8128 (Clamp sensor) 8129 (Flexible clamp sensor) 8312 (Power supply adaptor) 9132 (Magnetic carrying case) |  |  |  |  |  |  |  |  |  |  |  |  |
|
| |  | Set Model |  | |
 |  | KEW 6305-01 | | KEW 6305 × 1 |  | | MODEL 8125 × 3 | | 7141B (Voltage test lead set: 4pcs) × 1 | | 7148 (USB cable) × 1 | | 7170 (Power cord) × 1 | | 8326-02 (SD card [2GB]) × 1 | | 9125 (Carrying case) × 1 | | PC Software × 1 | | Battery × 6 | | Quick manual × 1 | | Calibration certificate | |
| 2. Kyoritsu 6310
| • | Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value (short term severity in 10 minutes value) and the Plt value (long term severity in 2 hours value) can be measured. | • | 12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis. | • | One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory. | • | Direct communication with PC via USB cable |
| | • | Built-in Input / Output Function of external signal enables the signal transmission to alarms. | • | 2-way power supply by AC and Battery, and Nickel hydrogen battery usable with rechargeable function. | • | Pull / Insert of CF card possible whenever on recording under the function of memory backup device. | • | Can monitor insulation at leakage current by using optional leak clamp sensors. | • | Built-in Print Screen Function enables to record display screen (Records 512 screens by using CF card: 1 screen 40KB). | • | Can display Waveform and Vector, and can confirm the wiring connection, too. | • | Complies fully with International Safety Standards IEC 61010-1 CAT.III 600V. |  |
* Attention for KEW6310 customers: | | Flicker measurements are possible with firmware of KEW6310 upgrade (Ver.2.01), PC software PQA Master upgrade (Ver. 2.01) and an optional accessory Flicker sensor KEW8325F. |
|
|
|  | |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Wiring connections |  |  |  | 1P 2W, 1P 3W, 3P 3W, 3P 4W |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Measurements and parameters |  |  |  | Voltage, Current, Frequency, Active power, Reactive power, Apparent power, Active energy, Reactive energy, Apparent energy, Power factor (cos θ), Neutral current, Demand, Harmonics, Quality (Swell/Dip/Instantaneous Stop, Transients/Over Voltage, Inrush Current, Unbalance Rate, IEC Flicker [Pst(1 min)*, Pst, Plt]), Phase Advance Condenser
(*Pst can be shown in details for 1 minute intervals.) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Other functions |  |  |  | Digital output function, External communication function, Scaling function |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Voltage : |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Ranges [RMS] |  |  |  | 150 / 300 / 600 /1000V (CF: 2.5 or less, 100% or less of each range) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Allowable input |  |  |  | 10~110% of each range (1000V range : 20%~) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Display ranges |  |  |  | 5~120% of each range |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Accuracy |  |  |  | |±0.3%rdg±0.2%f.s. (sine wave, 45~65Hz) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Current : |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Ranges [RMS] |  |  |  | 8128 ( | 50A | type ) | : | 1 / 5 / 10 / 20 / 50A | 8127 ( | 100A | type ) | : | 10 / 20 / 50 / 100A | 8126 ( | 200A | type ) | : | 20 / 50 / 100 / 200A | 8125 ( | 500A | type ) | : | 50 / 100 / 200 / 500A | 8124 ( | 1000A | type ) | : | 100 / 200 / 500 / 1000A | 8129 ( | 3000A | type ) | : | 300 / 1000 / 3000A | (CF:3.0 or less. 90% or less of each range) |
|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Allowable input |  |  |  | 10~110% of each range |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Display ranges |  |  |  | 1~120% of each range |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Accuracy |  |  |  | |±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45~65Hz) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Activa power accuracy |  |  |  | |±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor (Power factor 1, Sine wave, 45~65Hz) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Influence of power factor |  |  |  | |±1.0%rdg (reading at power factor 0.5 against power factor 1) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Frequency meter range |  |  |  | 40~70Hz |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Internal memory |  |  |  | 1.8MB | | | Measurement file (CSV) | : | 256kB×6 blocks (=1.536MB) | Screen file (BMP) | : | 32kB×7 blocks (=0.224MB) | Configuration file (KAS) | : | 32kB |
|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Display |  |  |  | 320×240 (RGB) Pixel, 3.5-inch color STN display |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Temperature & humidity range |  |  |  | 23ºC±5ºC, Relative humidity 85% or less (no condensation) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Storage Temperature & humidity range |  |  |  | -20ºC±60ºC, Relative humidity 85% or less(no condensation) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Operating Temperature & humidity range |  |  |  | 0ºC±40ºC, Relative humidity 85% or less(no condensation) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | PC Card type *1 |  |  |  | Compact flash card (Capacity: 32 / 64 / 128 / 256 / 512MB / 1 / 2 / 4 / 8GB)

* | The CF card larger than 2GB is usable, however, the possible stored size will be limited to 2GB. For example, when the CF card of 4GB or 8GB is used, the maximum stored size will be 2GB. |
|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Applicable standards |  |  |  | IEC 61010-1 CAT.III 600V Pollution degree 2 IEC 61010-031, IEC 61326 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Power supply |  |  |  | AC 100V ~ 240V±10% (45~65Hz) Alkaline size AA battery LR6 (9V 1.5V × 6) or Ni-MH (HR15-51) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Dimension |  |  |  | 175(L)×120(W)×68(D) mm |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Weight |  |  |  | approx. 900g (including batteries) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Accessories |  |  |  | 7141B (Voltage test lead set) 7148 (USB cable) 7170 (Power cord) 9125 (Carrying case) 8307 (Compact flash card 128MB) 8319 (CF Card reader) Input terminal plate (6-kind) Alkaline size AA battery (LR6) × 6 PQA MASTER (PC Software) Quick manual Cable marker × 32 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Optional accessories |  |  |  | 8124, 8125, 8126, 8127, 8128 (Load current clamp sensor) 8129 (Flexible clamp sensor) 8146, 8147, 8148 (Leakage & Load current clamp sensor) *2 8141, 8142, 8143 (Leakage clamp sensor) *2 8322 (Compact flash card 256MB) 8323 (Compact flash card 1GB) 8312 (Power supply adaptor) 8325F (Flicker sensor) 9132 (Carrying case (for instrument)) |  |  |  |  |  |  |  |  |  |  |  |  |
| *1: Please refer to here for the CF cards which checked. *2: Cannot be used for power measurement. | |
 | Set Model |  |
MODEL | Clamp Sensor | KEW 6310-01 | 8125 (500A) × 3 | KEW 6310-02 | 8125 (500A) × 2 | KEW 6310-03 | 8124 (1000A) × 3 | KEW 6310-04 | 8124 (1000A) × 2 | KEW 6310-05 | 8126 (200A) × 3 | KEW 6310-06 | 8126 (200A) × 2 | KEW 6310-07 | 8127 (100A) × 3 | KEW 6310-08 | 8127 (100A) × 2 | KEW 6310-09 | 8128 (5A) × 3 | KEW 6310-10 | 8128 (5A) × 2 | KEW 6310-11 | 8129-03 × 1 | KEW 6310-12 | 8129-02 × 1 |
|  |
 | Accessories |  |
 | | 6310 × 1 |  | 7141B (Voltage test lead set) | 7148 (USB cable) | 7170 (Power cord) | 9125 (Carrying case) | PQA MASTER (PC Software) | Input terminal plate (6-kind) | Quick manual | Alkaline size AA battery (LR6) × 6 | 8307 (Compact flash card 128MB) | Cable marker × 32 | 8319 (CF Card reader) |
|
|
|