Đồng hồ đo công suất

1.Kyoritsu 6305

THÔNG SỐ KỸ THUẬT:

+ Chỉ thị số
+ Sơ đồ nối dây : 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W
+ Điện áp : 150 / 300 / 600V
+ Dòng điện: 3000A
Phụ kiện bao gồm : 
+ 8125 (kìm đo 500A) 3 cái
+ 7141B (dây đo điện áp),
+ 7148 (Cáp USB),
+ 7170 (Dây nguồn),
+ 8326-02 (thẻ SD  [2GB]) × 1
+ 9125 (túi đựng),
Phần mềm PC , pin × 6, hướng dẫn sử dụng
Phụ kiện tùy chọn :
8124,8125,8126,8127,8128 (kìm đo). 
8129 (kìm đo dây mềm).
8312 (adapter nguồn)
8322 (Compact flash card 256MB)
8323 (Compact flash card 1GB)
9132 (Carrying case with magnet)
Wide range of clamp sensor up to 1000A on request.
Bảo hành : 12 tháng
Hãng sản xuất : Kyoritsu - Nhật
Xuất xứ : Nhật

Giá bán: 23.920.000 vnđ



Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems
Voltage, Current, Power Factor and Frequency measurements
Power analysis (Active, Apparent and Reactive power)
Energy analysis (Active, Apparent and Reactive power)
Active power accuracy: ±0.3%rdg±0.2%f.s.
Automatic wiring check function to prevent incorrect connections
Large memory capability (2GB) using built-in SD card interface
Real time & remote measurements using Android application
synchronous measurements between two units of KEW 6305
Wide selection of clamp sensors allow measurements from 0.1A to 3000A
The instrument automatically recognizes what kind of clamp sensor is connected to it
6305
 
CE
Windows software for data analysis and setting via USB port or Bluetooth
 
Free Android software "KEW smart 6305" is available
on "Google Play Store" (*)
  • Supporting Android ver. 2.2 - 4.0
  • WVGA (800 × 480) resolution or higher
(*)Please search "KEW Smart" in Google Play Store.
Communication charge may be incurred separately to download application.
NEWTRUE RMSUSBBluetooth ®
Wiring connections1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W
MeasurementsVoltage, Current, Frequency, Active power
ParametersApparent power, Reactive power, Active energy, Apparent energy,
Reactive energy, Power factor (cos θ), Neutral current
Voltage :
Ranges [RMS]150.0 / 300.0 / 600.0V
Allowable input10~110% of rating range
Display ranges5~130% of each range
Accuracy±0.2%rdg±0.2%f.s. (sine wave, 45~65Hz)
Current :
Ranges [RMS]
8128 (50A type ):1.000 / 5.000 / 10.00 / 25.00 / 50.00A / auto
8127 (100A type ):2.000 / 10.00 / 20.00 / 50.00 / 100.0A / auto
8126 (200A type ):4.000 / 20.00 / 40.00 / 100.0 / 200.0A / auto
8125 (500A type ):10.00 / 50.00 / 100.0 / 250.0 / 500.0A / auto
8124 (1000A type ):20.00 / 100.0 / 200.0 / 500.0 / 1000A / auto
8129 (3000A type ):300.0 / 1000 / 3000A
Allowable input10~110% of each range
Display ranges1~130% of each range
Accuracy±0.2%rdg±0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45~65Hz)
(*) +1%f.s. at the lowest range
Crest factorVoltage: up to 2.5, Current: up to 3.0 (with 90% fs or less)
Active power accuracy±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor
(*) +1%f.s. when the lowest current ranges is selected.
Effect of power factorActive power: ±1.0%rdg cos θ=±0.5 (PF=1)
Frequency meter range40.0~70.0Hz
Frequency meter accuracy±3dgt
Accuracy preconditionPF=1, Sine wave, 45~65Hz, 23ºC±5ºC
Display update period1 second
Operating temperature and humidity range0~+50ºC, less than 85%RH (without condensation)
Storage temperature and humidity range-20~+60ºC, less than 85%RH (without condensation)
PC communication interfaceUSB, Bluetooth
PC card interfaceSD card (2GB)
Applicable standardsIEC 61010-1 CAT.III 600V
Power supply (AC Line)AC100~240V±10% (50/60Hz)
Power supply (DC battery)LR6 or Ni-MH (HR-15-51) ×6 (Battery charger not included),
Battery life approx. 15h (LR6)
Power consumption10VA (max.)
Dimension175(L)×120(W)×65(D) mm
WeightApprox. 800g (including batteries)
Accessories7141B (Voltage test lead set: 4pcs)
7148 (USB cable)
7170 (Power cord)
9125 (Carrying case)
8326-02 (SD card 2GB)
KEW WINDOWS (PC Software)
Battery (LR6)×6
Quick manual
Calibration certificate
Optional81248125812681278128 (Clamp sensor)
8129 (Flexible clamp sensor)
8312 (Power supply adaptor)
9132 (Magnetic carrying case)
 
 Set Model
 
KEW 6305-01
 KEW 6305 × 1
 MODEL 8125 × 3
 7141B (Voltage test lead set: 4pcs) × 1
 7148 (USB cable) × 1
 7170 (Power cord) × 1
 8326-02 (SD card [2GB]) × 1
 9125 (Carrying case) × 1
 PC Software × 1
 Battery × 6
 Quick manual × 1
 Calibration certificate
 

2. Kyoritsu 6310


 
Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value (short term severity in 10 minutes value) and the Plt value (long term severity in 2 hours value) can be measured.
12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis.
One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory.
Direct communication with PC via USB cable
6310
CE
Built-in Input / Output Function of external signal enables the signal transmission to alarms.
2-way power supply by AC and Battery, and Nickel hydrogen battery usable with rechargeable function.
Pull / Insert of CF card possible whenever on recording under the function of memory backup device.
Can monitor insulation at leakage current by using optional leak clamp sensors.
Built-in Print Screen Function enables to record display screen
(Records 512 screens by using CF card: 1 screen 40KB).
Can display Waveform and Vector, and can confirm the wiring connection, too.
Complies fully with International Safety Standards IEC 61010-1 CAT.III 600V.
* Attention for KEW6310 customers:
 
Flicker measurements are possible with firmware of KEW6310 upgrade (Ver.2.01), PC software PQA Master upgrade (Ver. 2.01) and an optional accessory Flicker sensor KEW8325F.

TRUE RMS
 
Wiring connections1P 2W, 1P 3W, 3P 3W, 3P 4W
Measurements and parametersVoltage, Current, Frequency, Active power, Reactive power,
Apparent power, Active energy, Reactive energy, Apparent energy,
Power factor (cos θ), Neutral current, Demand, Harmonics,
Quality (Swell/Dip/Instantaneous Stop, Transients/Over Voltage, Inrush Current, Unbalance Rate, IEC Flicker [Pst(1 min)*, Pst, Plt]), Phase Advance Condenser

(*Pst can be shown in details for 1 minute intervals.)
Other functionsDigital output function, External communication function,
Scaling function
Voltage :
Ranges [RMS]150 / 300 / 600 /1000V (CF: 2.5 or less, 100% or less of each range)
Allowable input10~110% of each range (1000V range : 20%~)
Display ranges5~120% of each range
Accuracy|±0.3%rdg±0.2%f.s. (sine wave, 45~65Hz)
Current :
Ranges [RMS]
8128 (50A type ):1 / 5 / 10 / 20 / 50A
8127 (100A type ):10 / 20 / 50 / 100A
8126 (200A type ):20 / 50 / 100 / 200A
8125 (500A type ):50 / 100 / 200 / 500A
8124 (1000A type ):100 / 200 / 500 / 1000A
8129 (3000A type ):300 / 1000 / 3000A
(CF:3.0 or less. 90% or less of each range)
Allowable input10~110% of each range
Display ranges1~120% of each range
Accuracy|±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor
(sine wave, 45~65Hz)
Activa power accuracy|±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor
(Power factor 1, Sine wave, 45~65Hz)
Influence of power factor|±1.0%rdg (reading at power factor 0.5 against power factor 1)
Frequency meter range40~70Hz
Internal memory
1.8MB  
Measurement file (CSV):256kB×6 blocks (=1.536MB)
Screen file (BMP):32kB×7 blocks (=0.224MB)
Configuration file (KAS):32kB
Display320×240 (RGB) Pixel, 3.5-inch color STN display
Temperature & humidity range23ºC±5ºC, Relative humidity 85% or less (no condensation)
Storage Temperature & humidity range-20ºC±60ºC, Relative humidity 85% or less(no condensation)
Operating Temperature & humidity range0ºC±40ºC, Relative humidity 85% or less(no condensation)
PC Card type *1Compact flash card
(Capacity: 32 / 64 / 128 / 256 / 512MB / 1 / 2 / 4 / 8GB)

*The CF card larger than 2GB is usable, however, the possible stored size will be limited to 2GB. For example, when the CF card of 4GB or 8GB is used, the maximum stored size will be 2GB.
Applicable standardsIEC 61010-1 CAT.III 600V Pollution degree 2
IEC 61010-031, IEC 61326
Power supplyAC 100V ~ 240V±10% (45~65Hz)
Alkaline size AA battery LR6 (9V 1.5V × 6) or Ni-MH (HR15-51)
Dimension175(L)×120(W)×68(D) mm
Weightapprox. 900g (including batteries)
Accessories7141B (Voltage test lead set)
7148 (USB cable)
7170 (Power cord)
9125 (Carrying case)
8307 (Compact flash card 128MB)
8319 (CF Card reader)
Input terminal plate (6-kind)
Alkaline size AA battery (LR6) × 6
PQA MASTER (PC Software)
Quick manual
Cable marker × 32
Optional accessories81248125812681278128 (Load current clamp sensor)
8129 (Flexible clamp sensor)
814681478148 (Leakage & Load current clamp sensor) *2
814181428143 (Leakage clamp sensor) *2
8322 (Compact flash card 256MB)
8323 (Compact flash card 1GB)
8312 (Power supply adaptor)
8325F (Flicker sensor)
9132 (Carrying case (for instrument))
*1: Please refer to here for the CF cards which checked.
*2: Cannot be used for power measurement.
 
 Set Model

MODELClamp Sensor
KEW 6310-018125 (500A) × 3
KEW 6310-028125 (500A) × 2
KEW 6310-038124 (1000A) × 3
KEW 6310-048124 (1000A) × 2
KEW 6310-058126 (200A) × 3
KEW 6310-068126 (200A) × 2
KEW 6310-078127 (100A) × 3
KEW 6310-088127 (100A) × 2
KEW 6310-098128 (5A) × 3
KEW 6310-108128 (5A) × 2
KEW 6310-118129-03 × 1
KEW 6310-128129-02 × 1


 Accessories
 
6310 × 1
7141B (Voltage test lead set)
7148 (USB cable)
7170 (Power cord)
9125 (Carrying case)
PQA MASTER (PC Software)
Input terminal plate (6-kind)
Quick manual
Alkaline size AA battery (LR6) × 6
8307 (Compact flash card 128MB)
Cable marker × 32
8319 (CF Card reader)



CÔNG TY TNHH TRUNG AN

Địa Chỉ: 124/46 Phan Huy Ích , P. 15, Q. Tân Bình, Tp. HCM

Tel : (08) 38150410 - Fax: (08) 38150410

Hotline: 091 7080310 (Mr. Trung)-0909.67.4225 (Mr.Tín)-097 8057811 (Ms. Trinh)

Email: trungankd@gmail.com

Website: https://www.sites.google.com/site/congtytnhhtrungan/

https://www.facebook.com/congtytnhhtrungan

STK: 102010002108889 Ngân Hàng Vietinbank Chi Nhánh TP.HCM